Features
- Low Insertion loss and Low PDL
- Good channel-to-channel uniformity
- Wide Operating Wavelength: From 1260nm to 1650nm
- Wide Operating Temperature: From -40℃ to 85℃
- High Reliability and Stability
- Stability Telecordia GR-1221 and GR-1209
Components through TLC-Certified, Conform to YD1117-2001
Specification
Type | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |||
Working Bandwidth (nm) | 1260-1650 | ||||||||
Insertion Loss (dB) Max w/o connectors | 3.8 | 7.1 | 10.2 | 13.5 | 16.8 | 20.2 | |||
Insertion Loss (dB) Max with connectors | 4.1 | 7.4 | 10.5 | 13.8 | 17.1 | 20.5 | |||
Wavelength Dependent Loss (dB) Max. |
0.2 | 0.3 | 0.4 | 0.6 | 0.8 | 1 | |||
Return Loss (dB) Min.(APC) | 55 | ||||||||
Temperature Dependent Loss(dB) Max |
0.5 | ||||||||
Stability in Hot Environment (dB/°C) Max |
1 | ||||||||
Uniformity (dB) Max | 0.6 | 0.6 | 0.8 | 1.1 | 1.5 | 2 | |||
Polarization Dependent Loss (dB) Max |
0.2 | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | |||
Orientation (dB) Min | 50 | ||||||||
Power (mW) Max | 300 | ||||||||
Steel Tube Size(mm) | 60*7*4 | 60*7*4 | 60*7*4 | 60*12*4 | 80*20*6 | 100*40*6 | |||
Optical Fiber | SMF-28, G657A1, G657A2 or customized | ||||||||
Input / Output length | 1meter standard or customized length | ||||||||
Cable Color | White or customized | ||||||||
Cable Diameter | 250um or 900um | ||||||||
Connector | SC APC, SC UPC or without connector | ||||||||
Operating Temperature (℃) | -40 to 85 | ||||||||
Storage Temperature (℃) | -40 to 85 | ||||||||
Standard | Telcordia GR-1209, Telcordia GR-1221, IEC 61300, IEC 6175321 |
Application
Fiber to The Point (FTTX)
Fiber to The Home (FTTH)
Passive Optical Networks (PON)
Gigabit Passive Optical Networks (GPON)
Local Area Networks (LAN)
Cable Television (CATV)
Test Equipment
Download